beam-scan: specification#

Options and examples: beam-scan. Writer B, producer obdeect sources beam-scan.

Validation#

  • -r must be finite and positive: beam-scan: radius must be finite and positive.

  • The defaults of -x, -y, -h are derived from 123 cm and do not follow a later -r.

  • Photons per position: finite, >= 0, <= 2^53, else beam-scan: photons per position must be finite, >= 0 and at most 2^53.

Plan#

  • Fixed: run number 1, observation level 2150 m, atmosphere_id 1, 100 photons per position, bunch 1, wavelength 400 nm (wavelength_min = wavelength_max = 400), one telescope id 1 at (0, 0, 0) with radius r/100 m, 1 event, one case.

  • Scan positions in cm, by repeated addition in double precision (this fixes the count): x = xpos; x < xpos + 0.4 r; x += 0.001 r at y = ypos; then y = ypos; y < ypos + 0.2 r; y += 0.001 r at x = xpos.

  • Position k = 0, 1, ... (over both lines) is one emission: emitter at (x, y, height)/100 m, pointing (0, 0, -1), FixedAngle(0), Fixed 400 nm, Gauss sigma 0 (t = 0), Source.photons = 100, bunch 1, seed seed + k, no target.

  • Total rows 100 x positions (default: more than 500 and fewer than 700 positions), all w = 1, cz = -1, z = 0.0615.

  • XylsOptions has the fields photons_per_position and bunch size: with bunch 2, photons 6, each position gives 3 rows of w = 2.