simtools-analyze-flasher-response#

Plot gain-resolved pulse response from a simulated flasher intensity sequence.

Analyze raw HG and LG calibration waveforms from a flasher intensity sequence. The application writes per-event and summary ECSV tables and a PDF containing peak, ADC sum, width, and mean-waveform plots. Error bars show event-to-event standard deviations; the peak curve is the mean of individual-event peaks.

Supply one file per intensity, or one file containing all steps in declared order. events_per_level must match the actual counts; one value broadcasts to all steps. Analyze only scan files containing the declared calibration events. The illumination axis is the requested photon count, not detected p.e.

Monitoring pedestals are converted to per-sample values separately for both gains. If monitoring is unavailable, provide an explicit per-sample pedestal. There is no automatic baseline estimate from possibly saturated pulse tails. A pulse lacking width crossings inside the readout window is flagged as truncated; its ADC sum covers only the recorded window.

Command line arguments#

options#

–help

show this help message and exit

–simtel_files

One file per intensity, or one ordered scan file

Required.

–illumination

Requested photons per intensity step, in file/event order

Required.

–events_per_level

Expected events per step; one count broadcasts to all steps

Required.

–pixels

Pixel IDs to analyze independently

Default: [0].

–pedestal

Explicit per-sample pedestal for both gains; otherwise monitoring

–width_fraction

Fraction of pulse peak defining its width

Default: 0.95.

–threshold_adc

Absolute width threshold above pedestal, overriding the fraction

simulation model#

–telescope

telescope model name (e.g., LSTN-01, SSTS-design, …)

application#

–show_options

Print available values for a supported option and exit.

Workflow#

Run the configurations under tests/integration_tests/config/ with simtools-run-application --config_file <workflow.yml> --replace __OUTPUT__=<directory>. The direct-injection and full-simulation configurations run the existing flasher application followed by the analyzer. Use more events and intensity levels for statistical studies. Synthetic response tables test software behavior; comparison with measured curves requires measured tables and matching camera settings.

The saturation scan workflows record a longer readout window to include broadened pulses. For whole-camera bright flashes, set MAX_PHOTOELECTRONS=25000000 before running the workflow; the integration test sets this capacity automatically. The full-simulation smoke test uses photon bunches of 100 for speed. Use bunches of one and more events when studying photon statistics or comparing measurements. The direct-injection workflow also writes a matched linear/clipped control under linear/, with the non-linear pulse tables disabled.

LST direct_injection saturation scan#

Simulate four illumination levels and analyze both raw gain channels.

Application: simtools-simulate-flasher

Integration test: validate_saturation_direct_injection_lst.yml

Command

simtools-simulate-flasher --config tests/integration_tests/config/validate_saturation_direct_injection_lst.yml

Configuration

run_mode: direct_injection
light_source_type: flat_fielding
telescopes:
- LSTN-01
model_version: 8.0.0
site: North
run_number: 100
number_of_events: 2
flasher_photons:
- 100
- 500
- 3000
- 10000
label: saturation
output_path: __OUTPUT__/simulation
sim_telarray_seed:
- 101
- 102
overwrite_model_parameters: '{"LSTN-01": {"fadc_bins": 120, "fadc_sum_bins": 100}}'